Getting Started Manual Rev. 2.0
MCS-MAGNUM HARDWARE VERSION 7.1+
Vue de la page 0
1 2 3 4 5 6 ... 24 25

Résumé du contenu

Page 1

Getting Started Manual Rev. 2.0 MCS-MAGNUM HARDWARE VERSION 7.1+

Page 2 - Revision Page

GETTING STARTED MANUAL REVISION 2.0 10 Preparing to Upgrade an Existing Chiller Step 1- Open MCS Supplied Upgrade Kit (Usually fits in a 16

Page 3 - Table of Contents

GETTING STARTED MANUAL REVISION 2.0 11  All setpoints should be displayed on the MCS-Magnum and reviewed for correctness. Specific attent

Page 4 - MCS 485 Network

GETTING STARTED MANUAL REVISION 2.0 12 Keypad Display Screens To reach the Main Menu press the Menu button after powering up. Based on the

Page 5

GETTING STARTED MANUAL REVISION 2.0 13 Pressing the Page Down button shows the following Liquid Line Solenoid Status screen: ACTUAL DISPLA

Page 6

GETTING STARTED MANUAL REVISION 2.0 14 Pressing the Page Down button shows the next 4 Sensor Inputs: ACTUAL DISPLAY DESCRIP

Page 7 - Crossover Ethernet Cable

GETTING STARTED MANUAL REVISION 2.0 15 Pressing the Page Down button shows the next 4 setpoints: ACTUAL DISPLAY DESCRIPTION

Page 8 - Requirements for PC Software

GETTING STARTED MANUAL REVISION 2.0 16 Lockout Alarms Selecting the ‘Lckout ALM’ menu option shows the first 2 Lockout alarms (Lockout alar

Page 9

GETTING STARTED MANUAL REVISION 2.0 17 To get authorized on Magnum do the following: 1. Press ‘Menu’ 2. Using , , , or  to position the

Page 10

GETTING STARTED MANUAL REVISION 2.0 18 BMS Communication Protocols The MCS-Magnum supports BACnet IP, Modbus RTU, Modbus TCP/IP, and Johnso

Page 11

GETTING STARTED MANUAL REVISION 2.0 19 MCS-Magnum BMS protocols settings Bacnet Over IP The BACNET DEVICE ID is a five-digit number. The fi

Page 12 - Keypad Display Screens

GETTING STARTED MANUAL REVISION 2.0 2 The MCS Commitment: Our commitment is to provide practical solutions for the industry’s needs and to

Page 13

GETTING STARTED MANUAL REVISION 2.0 20  Press the Menu key, select Serv Tools, and then press the Enter key.  Select Ethernet Network t

Page 14

GETTING STARTED MANUAL REVISION 2.0 21 Trouble Shooting Quick Reference Sheet (A complete trouble shooting guide is available from our web

Page 15

GETTING STARTED MANUAL REVISION 2.0 22

Page 16 - Authorization Function

GETTING STARTED MANUAL REVISION 2.0 23

Page 17 - Schedule Function

GETTING STARTED MANUAL REVISION 2.0 24

Page 18 - BMS Communication Protocols

GETTING STARTED MANUAL REVISION 2.0 25

Page 19

GETTING STARTED MANUAL REVISION 2.0 3 Table of Contents Revision Page ...

Page 20

GETTING STARTED MANUAL REVISION 2.0 4 Introduction to Magnum V8 Software Magnum V8 software has been designed to control many different typ

Page 21

GETTING STARTED MANUAL REVISION 2.0 5 RS485 Network with Local RS232 Communications RS 232 RS 485

Page 22

GETTING STARTED MANUAL REVISION 2.0 6 RS485 Network with Remote Modem Communications RS 485

Page 23

GETTING STARTED MANUAL REVISION 2.0 7 Crossover Ethernet Cable Connection Crossover Ethernet Cable

Page 24

GETTING STARTED MANUAL REVISION 2.0 8 PC Support Software for Magnum MCS-Connect provides both local and remote communications to the Magnu

Page 25

GETTING STARTED MANUAL REVISION 2.0 9 MCS-MAGNUM Revision 7.0 and Higher PWR Input Terminal Ten (10) Relay Output terminals. (COMMON. NO,